Sign In | Join Free | My wneducation.com |
|
Brand Name : GAOXIN
Model Number : GX-600-ZD
Place of Origin : China
MOQ : 1set
Price : negotiation
Payment Terms : FOB Shenzhen
Supply Ability : 50 set per month
Delivery Time : 15 working days
Packaging Details : Non-fumigation wooden box
Certification : ISO
Frequency Range : DC1~3000 Hz
Maximum sinusoidal excitation force : 300Kg.f peak
Maximum random excitation force : 300Kg.f r.ms
Maximum impact excitation force : 600Kg.f peak
Maximum speed : 1.8m/s
Maximum acceleration : 100G(980 m/s2)
First order resonant frequency : 2500Hz
Maximum load (dynamic circle) : 120kg
Electromagnetic Vibration Test Bench
GX-600-ZD
Test type: sin vibration; random vibration
Frequency range: 2-4000Hz
System Principle Diagram
Electromagnetic excitation generator | ||||||
Maximum sinusoidal excitation force | 300Kg.f peak | |||||
Maximum random excitation force | 300Kg.f r.ms | |||||
Maximum impact excitation force | 600Kg.f peak | |||||
Frequency Range | DC1~3000 Hz | |||||
Maximum displacement | 25 mm p-p | |||||
Maximum speed | 1.8m/s | |||||
Maximum acceleration | 100G(980 m/s2) | |||||
First order resonant frequency | 2500Hz | |||||
F=M.A | ||||||
5G(49m/s2) | 10G(98m/s2) | 20G(196m/s2) | 30G(294m/s2) | |||
57kg | 27kg | 12kg | 7kg | |||
Maximum load (dynamic circle) | 120 kg | |||||
Vibration isolation frequency | 2.5 Hz | |||||
Moving coil diameter (work surface diameter) | Ф150 mm | |||||
Vertical expansion countertop | 400*400 mm | |||||
Extended countertop equivalent quality | 15 kg | |||||
Dynamic mass | 3kg | |||||
Extended table top load | 90Kg | |||||
Countertop screw | 13×M8 | |||||
Magnetic leakage | <10gauss | |||||
Equipment size | 750mm×560mm×670mm | |||||
equipment weight | About 460Kg | |||||
SA-3K Digital switching power amplifier | ||||||
Output Power | 4KVA | |||||
The output voltage: | 100V | |||||
Output current: | 30A | |||||
Signal to noise ratio: | ≥65dB | |||||
Harmonic distortion (resistive load): | <1.0% | |||||
Output voltage measurement error: | ≤5% | |||||
Output current measurement error: | ≤5% | |||||
Output current crest factor: | ≥3 | |||||
DC stability: | The output zero drift is not greater than 50mv/8h | |||||
Frequency response 5-3500Hz: | ±3dB | |||||
Amplifier size | 720mm×545mm×1270mm | |||||
Weight | 230KG | |||||
Servo protection system | ||||||
Function | Temperature, wind pressure, over-displacement, over-voltage, over-current, input under-voltage, external fault, control power, logic fault, input deficiency. | |||||
Digital vibration controller VCSusb-2 | ||||||
Hardware Configuration | 2 channel input, 1 output channel | |||||
Control computer | Original Lenovo computer, LCD display (including keyboard / optical mouse) | |||||
software | Chinese/English operation for time domain and frequency domain analysis, signal source, sine sweep analysis, etc. It can automatically generate WORD test report, signal and data display, storage, set test parameters and analysis functions. | |||||
Operation system | Windows 2000/ XP | |||||
Accelerometer B&W | Frequency range: 1-12000Hz Sensitivity: 50mv/g Temperature range: -24 - 250 ° C | |||||
BL-300 Cooling fan (with speaker) | ||||||
Fan power: | 1.1 KW | |||||
flow | 1404m3 /h | |||||
Wind pressure | 1000Pa | |||||
Electrical requirements: | ||||||
power supply | 3 phase, 380V/50Hz, 15 KVA |